Timer disabled
5 minutes
10 minutes
15 minutes
Time delay settings
SELV switch connector
(observe polarity)
N E L
N E L
Sensor
Detector lead supplied with detector.
Where detectors connect to a single box a dual
lead is available VITM4-LD3-PRM.
Sensor
Automatic on, automatic off
Manual on, automatic off
Low voltage (SELV) wiring
No requirement for:
Containment
RCDs
No mains voltage switch wires routed along walls removes the need for RCD protection under the IEE 17th Edition regulations.
The VITM4-SELVMOD module allows switches in parallel for 2-way and intermediate switching.
Optional time delay function.
The same switch can be used when multiple Vitesse Modular boxes are connected to different phases.
+
-
+
-
Momentary or latching switches
(momentary onlypush and hold to
reset)
Detector lead supplied with detector.
Where detectors connect to a single box a dual
lead is available VITM4-LD3-B.
Presence detector connections
Absence detector connections