The EBMHS series of miniature PIR (passive infrared)
presence detectors provide automatic control of lighting
loads with optional manual control.
Three models are available: premium, direct dim, and
analogue dim all of which will switch incandescent,
fluorescent and compact fluorescent lighting. The direct
dim variant controls DALI or DSI digital dimming ballasts
whilst the analogue dim variant controls 1-10V dimming
ballasts.
The unit detects movement using a PIR sensor and turns
the load on. When an area is no longer occupied the load
will switch off after an adjustable time out period.
These units come complete with clips allowing unobtrusive
flush mounting into ceiling tiles or solid ceilings.
All functionality is fully programmable using an IR handset.
Features
Miniature HS PIR Presence Detector (standalone)
EBMHS
Product Guide
Standard power supply
PIR Sensor
Detects movement within the unit’s detection range,
allowing load control in response to changes in occupancy.
IR Receiver
Receives control and programming commands from an
IR (infrared) handset.
Light Level Sensor
Measures the overall light level in the detection area
Status LEDs
The LED flashes Red to indicate the following:
RJ11 connector
The sensor head has a flying lead with a RJ11 plug at the
end plugs into the RJ11 socket on the power supply.
Power supply
This power supply has a 6A relay. It also has connections
for an external switch that can be used to turn on the load
when absence detection mode has been set or raised /
lowered with dimming variants.
Walk Test LED active
when movement is detected
Valid setting received
Dimming version shown
Sensor head
PIR lens
which covers...
IR Receiver
Light Level Sensor
Status LED
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Product Guide

Overview The EBMHS series of miniature PIR (passive infrared) presence detectors provide automatic control of lighting loads with optional manual

Seite 2 - Detection diagram

10 Dimensions Head end cap Flush ring Sensor head Power supply Brackets 25 19 31 1 Ø38

Seite 3 - Sensor functionality

11 This page intentionally left blank

Seite 4

12 Due to our policy of continual product improvement CP Electronics reserves the right to alter the specification of this product without prior not

Seite 5 - EBMHS-PRM - non-dimming

2 Detection diagram Range Walk towards Walk across Height Range Diameter 7m 10m 2.8m 5m Height Range Diameter 7m 16m 2.8m 9m Note: illustratio

Seite 6 - Power-up test procedure

3 The product is designed to be mounted directly to a luminaire, either on the inside or outside. The detector should be sited so that the occupants

Seite 7 - SHIFT 1 SHIFT 2

4 Installation Flush mounting Side mounting The product can be mounted using the flush mount ring as shown. If flush mounting in a material that is

Seite 8

5 Wiring diagrams - standard power supply Wire the products as shown in the diagrams. All switches are optional, however the dimming variants can ha

Seite 9 - Advanced programming

6 The UNLCDHS has the ability to read back the settings stored in a device. To read back individual parameters  Navigate to the parameter and pres

Seite 10 - Dimensions

7 Basic programming - PRM, DD and AD variants Parameter Name Default Value 0 1 2 3 UHS5 Handset Graphics Description Button Activation

Seite 11

8 Advanced programming Parameter Name Default Value Range / Options Description UHS5 UNLCDHS Detector Parameters Walk Test LED Off On or O

Seite 12 - Part numbers

9 Parameter Name Default Value Range / Options Description UHS5 UNLCDHS Channel 1 –Switching Channel Detection Mode Presence Presence or A